首页> 生物试剂> 其他生物试剂> 其他> Transfer SKU RNASE ALERT QC SYSTEM 480 ASSAYS V2,4479769,赛默飞世尔

Transfer SKU RNASE ALERT QC SYSTEM 480 ASSAYS V2,4479769,赛默飞世尔

市场价: 询价 / 套
在线询价
优    惠: 请询价
订货号 7DK5450
品牌型号 赛默飞世尔 4479769
货期 询货期
最小订货量 1套
联系我们
  • 400-920-3909
  • 商品介绍
  • 规格参数
  • 包装参数
产品介绍 Product Description
规格
Product Line: RNaseAlert®
Reagent Type: RNase Control Reagent
储存
Store at -20°C:
5 tubes of RNaseAlert® Substrate v2
5 mL 10X RNaseAlert Lab Test Buffer
500 µL RNase A

Store at room temperature:
250 mL RNaseZap® Solution

Store at any temperature:
50 mL Nuclease-free Water
描述

The RNaseAlert® QC System v2 detects RNase activity in a convenient and sensitive fluorimetric assay that delivers results in real time. This version contains a substrate that is ~60% more sensitive than the previous version. The kit contains sufficient reagents for 5 x 96 (480) high-throughput assays.

Features of RnaseAlert® QC System v2:

• Detects as little as ~0.3 pg of RNase A with a fluorometer
• Simple, straight-forward, 30-minute assay
• Designed to monitor RNase activity in column fractions during protein purification
• Use with DNaseAlert™ QC System to quantitatively detect both RNases and DNases in the same sample

The RNaseAlert® QC System v2 uses a new, more sensitive, novel RNA substrate tagged with a fluorescent reporter molecule (fluor) on one end and a quencher on the other. In the absence of RNases, the physical proximity of the quencher dampens fluorescence from the fluor to extremely low levels. When RNases are present, however, the RNA substrate is cleaved, and the fluor and quencher are spatially separated in solution. This causes the fluor to emit a bright green signal when excited by light of the appropriate wavelength.

Fluorescence can be readily detected with a filter-based or monochromator-based fluorometer. Since the fluorescence of the RNaseAlert® substrate increases over time when RNase activity is present, results monitored with a fluorometer can be evaluated kinetically. The sequence of the RNaseAlert® substrate has been carefully optimized to detect several RNases, including RNase A, RNase T1, RNase I, micrococcal nuclease, S1 nuclease, mung bean nuclease, and Benzonase®.

Rapid and Convenient Protocol
The RNaseAlert® procedure requires just minutes to set up. The lyophilized, fluorescent substrate is reconstituted in the supplied tube and incubated with the test solution for a few minutes. The results are then read on a fluorometer. Samples that noticeably fluoresce compared to the negative control are contaminated and should not be used with RNA. Nuclease-free water and RNase A are provided for use as controls.

Accessory Product
The RNaseAlert® QC System v2 is fully compatible with the DNaseAlert™ QC System. Since the DNaseAlert™ substrate contains a fluorescent tag that is spectrally distinct from RNaseAlert® substrate, the two kits can be used simultaneously for quantitative real-time analyses of both RNases and DNases within a single sample.

长度(mm)
宽度(mm)
高度(mm)
重量(kg)
猜你喜欢

在线
客服

在线客服服务时间:09:00-18:00

客服
热线

400-920-3909
客服服务热线 周一至周五(09:00-18:00)

微信
咨询

微信小程序 7X24小时在线咨询