规格 |
|
Product Line: | Pierce™ |
Workflow Step: | In-Process Testing |
Detection Method: | Fluorescent |
Final Product Type: | Peptide |
For Use With (Equipment): | Microplate Reader |
Starting Material: | Peptides, Protease-digested protein |
Description: | Quantitative Fluorometric Peptide Assay, 500 Assay, Fluorescent Detection Method, 2 to 8°C Storage, For Use With Equipment Microplate Reader, Recommended For Use With Peptide Mixtures and Synthetic |
Quantity: | 500 Assay(s) |
储存 |
|
Fluorometric Peptide Assay Reagent, 4 x 2.5 mL Fluorometric Peptide Assay Buffer, 50 mL Peptide Digest Assay Standard, 1.5 mL Store in refrigerator (2–8°C). |
描述 |
The Thermo Scientific™ Pierce™ Quantitative Fluorescent Peptide Assay is a sensitive, mix-and-read fluorescent microplate assay for the quantitative measurement of peptides and peptide mixtures.
• Sensitive—accurately detect as little as 5.0 µg/mL of single peptides or peptide mixtures
• Robust— assay performance rigorously tested using both peptides and peptide digest mixtures
• Robust peptide digest standard—kit includes a validated peptide digest standard for improved reproducibility of quantitation
• Compatible—works with many reagents, including those used in mass spectrometry sample preparation
• Convenient—easy mix-and-read format and stable fluorescent signal that may be read in as little as 5 minutes up to several hours
The Pierce Quantitative Fluorescent Peptide Assay reagents include peptide assay buffer, fluorescent peptide labeling reagent, and a peptide digest assay standard for the quantitative measurement of peptide concentrations. In this assay, peptides are specifically labeled at the amino-terminus using an amine-reactive fluorescent reagent, and the fluorescently labeled peptides are detected using ex390/em475.
Because of the labeling mechanism of the fluorescent assay reagent, this assay is suitable for the quantitative measurement of synthetic peptides as well as peptide digest mixtures. A high quality peptide digest reference standard is included for use in generating linear standard curves and as a calibration control for improved accuracy and reproducibility. This sensitive assay requires only 10 µL of sample, produces a linear response with increasing peptide concentrations (5–1000 μg/mL), and results in a stable final fluorescence that can be detected in as little as five minutes.
Applications:
• Recommended for use with peptide mixtures and synthetic peptides with an unblocked amino-terminus (amino-terminus-labeled peptides, such as TMT-labeled peptides, are not compatible with this assay)
• Normalizing sample concentrations for quantitative downstream applications
• Normalizing sample loading volumes for LC, MS, and LC/MS applications
• Measuring recovery after peptide clean-up procedures.