首页> 生物试剂> 其他生物试剂> 其他> GAUSSIA-FIREFLY LUCIFERASE DUAL ASSAY KIT, 100 REACTIONS,16181,赛默飞世尔

GAUSSIA-FIREFLY LUCIFERASE DUAL ASSAY KIT, 100 REACTIONS,16181,赛默飞世尔

市场价: 询价 / 套
在线询价
优    惠: 请询价
订货号 6BR344
品牌型号 赛默飞世尔 16181
货期 询货期
最小订货量 1套
联系我们
  • 400-920-3909
  • 商品介绍
  • 规格参数
  • 包装参数
产品介绍 Product Description
规格
Assay: Reporter Enzyme, Luciferase Reporter Assay
Compatible Cells: Mammalian Cells
Detection Method: Bioluminescent
For Use With (Equipment): Luminometer (Microplate)
Format: 384-well plate, 96-well plate
Label Type: Enzyme Labeled
Product Line: Pierce™
Substrate: Coelenterazine, D-Luciferin
Substrate Properties: Chemical Substrate
Substrate Type: Luciferase Substrate
Target Enzyme: Luciferase, Firefly Luciferase, Gaussia Luciferase
Technique: Enhanced Chemiluminescence
Quantity: 100 rxn kit
储存
• Gaussia-Firefly Dual Assay Buffer, 5 mL, store at 4°C
• Coelenterazine (1X), 5 µL, store at -80°C
• D-Luciferin, Lyophilized, 3 mg, store at 4°C
• 2X Cell Lysis Buffer, 6 mL, store at room temperature

Upon receipt store kit at -80°C or store individual components as indicated above.
描述

The Thermo Scientific Pierce Gaussia-Firefly Luciferase Dual Assay Kit provides the necessary reagents to simultaneously detect intracellular Gaussia and Red Firefly luciferase activity in mammalian whole cell lysates.

Features of the Gaussia-Firefly Luciferase Dual Assay Kit:

Simultaneous—concurrent, filter-based, wavelength-separated detection of two luciferase activities
Sensitive—measure bright blue Gaussia and red firefly luciferase activities in the same sample
Fast—no quenching step required, unlike in traditional sequential dual assays
Multiplex—capable of quantitating two cellular activities in the same sample(s)

The Pierce Gaussia-Firefly Luciferase Dual Assay Kit is a highly sensitive assay that allows for the simultaneous detection of Gaussia and Red Firefly luciferase activity. Gaussia luciferase acts as an experimental reporter with constitutively active red firefly as a normalization control. As shown in the animation videos below, this reporter-and-control combination enables simultaneous monitoring of experimental reporter and control luciferase activities in a single-read assay without the need for two-step addition of substrate reagents or quenching. The assay working solution contains substrates for both luciferases, and the reactions occur simultaneously with flash-type kinetics. The resulting luminescent signals are spectrally resolvable using filters. In a single sample, researchers can assay transcriptional activity of regulatory elements, signal transduction pathways, and effects of activators or inhibitors.

Includes:
Cell lysis buffer, reaction buffer, and substrates coelenterazine and D-luciferin

Requires:
Gaussia and Red Firefly luciferase reporters; Filter sets in the ranges of 425 to 525nm for Gaussia Luc and 615 to 675nm for Red Firefly Luc. Luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan Ascent and Varioskan Flash Microplate Readers; Injector required for assessing more than 24 wells at a time.

Applications:
• Study two regulatory elements at the same time
• Monitor two signaling pathways simultaneously
• Enable studying more than one target per screen (e.g. off-target effects)

Application Videos:
Gaussia luciferase produces brighter bioluminescent signal than firefly and native Renilla luciferases. The bioluminescent signal (λmax= 470nm) produced by Gaussia luciferase results from the oxidation of coelenterazine. This reaction does not require adenosine triphosphate (ATP) or other cofactors. Red firefly luciferase is a mutant form of the Japanese firefly luciferase from Luciola cruciata. This luciferase produces a red-shifted emission spectrum (λmax= 613nm) that results from the oxidation of D-luciferin in the presence of ATP. Red firefly and Gaussia luciferases are used in the dual assay because the light output is spectrally resolvable.

More Product Data
• Highly sensitive multiplex luciferase reporter assays
• Simultaneous dual-emission detection of luciferase reporter assays
• Activation of the antioxidant response pathway by pesticide chemicals

长度(mm)
宽度(mm)
高度(mm)
重量(kg)
猜你喜欢

在线
客服

在线客服服务时间:09:00-18:00

客服
热线

400-920-3909
客服服务热线 周一至周五(09:00-18:00)

微信
咨询

微信小程序 7X24小时在线咨询