首页> 生物试剂> 其他生物试剂> 其他> AMPLEX RED GALACTOSE/G 1 KIT,A22179,Invitrogen

AMPLEX RED GALACTOSE/G 1 KIT,A22179,Invitrogen

市场价: 询价 / 套
在线询价
优    惠: 请询价
订货号 5PH5523
品牌型号 Invitrogen A22179
货期 询货期
最小订货量 1套
联系我们
  • 400-920-3909
  • 商品介绍
  • 规格参数
  • 包装参数
产品介绍 Product Description
规格
Product Line: Amplex™
Shipping Condition: Room Temperature
Detection Method: Fluorescent
For Use With (Equipment): Microplate Reader, Spectrophotometer, Fluorometer
Label Type: Other Label(s) or Dye(s)
Label or Dye: Amplex® Red
Format: Tube(s), 96-well plate
储存
Store in freezer (-5 to -30°C) and protect from light.
描述

The Amplex® Red Galactose/Galactose Oxidase Assay Kit provides a sensitive and simple method for detecting galactose oxidase activity or galactose using a fluorescence microplate reader or fluorometer.

See our complete line of Fluorescence Microplate assays.

• Detect concentrations as low as 2 mU/mL of galactose oxidase activity or 4 µM galactose
• Format allows for multiple time point measurements
• Designed for minimal autofluorescence interference

Galactose oxidase is an important tool in the detection of galactose in biological fluids. The Amplex® Red Galactose/Galactose Oxidase Assay Kit provides an ultrasensitive method for detecting galactose or for monitoring galactose oxidase activity. Galactose oxidase catalyzes the oxidation of galactose at the C6 position and generates hydrogen peroxide. In the presence of horseradish peroxidase (HRP), hydrogen peroxide reacts in a 1:1 stoichiometric ratio with the Amplex® Red reagent to generate the red-fluorescent compound resorufin.

Because resorufin has absorption and fluorescence emission maxima of approximately 571 nm and 585 nm, respectively, there is little interference from autofluorescence in most biological samples.

Use Amplex® Red Assays for a Broad Range of Investigations
A wide variety of validated Amplex® Red assays are available for studying cell signaling and lipids, neurobiology, inflammation and immune function, and metabolism. We also offer Amplex® UltraRed Reagent (Cat. No. A36006), a second-generation reagent providing greater sensitivity and brighter fluorescence, and the Amplex® Red/UltraRed Stop Reagent (Cat. No. A33855). The Amplex® Red/UltraRed Stop Reagent provides convenience and control by allowing the fluorescence signal-generating reaction to be terminated at a user-determined time point. After addition of the stop reagent, the fluorescence signal remains stable for at least three hours. Custom assay design and packaging are also available.

长度(mm)
宽度(mm)
高度(mm)
重量(kg)
猜你喜欢

在线
客服

在线客服服务时间:09:00-18:00

客服
热线

400-920-3909
客服服务热线 周一至周五(09:00-18:00)

微信
咨询

微信小程序 7X24小时在线咨询