首页> 生物试剂> 其他生物试剂> 其他> Transfer SKU RNASEALERT QC SYSTEM 480 ASSAYS,AM1966,赛默飞世尔

Transfer SKU RNASEALERT QC SYSTEM 480 ASSAYS,AM1966,赛默飞世尔

市场价: 询价 / 套
在线询价
优    惠: 请询价
订货号 5JU2959
品牌型号 赛默飞世尔 AM1966
货期 询货期
最小订货量 1套
联系我们
  • 400-920-3909
  • 商品介绍
  • 规格参数
  • 包装参数
产品介绍 Product Description
规格
Form: Lyophilized
Product Line: Ambion™, RNaseAlert®
Reagent Type: RNase Control Reagent
Shipping Condition: Dry Ice
储存
Store RnaseAlert Substrate, 10X Rnase Alert Buffer, Rnase A, and TE Buffer pH 7.0 at -20°C; store RNaseZap™Solution and Nuclease-free Water at room temperature.
描述

Ambion® RNaseAlert® QC System is a patent-pending technology detects RNase activity in a convenient and sensitive fluorimetric assay that delivers results in real time. Contain sufficient reagents for 5 × 96 high throughput assays.

• Detects as little as 3.5 x 10-7 units (~0.5 pg) of RNase A with a fluorometer
• Simple, straightforward 30 min assay
• Monitor RNase activity in column fractions during protein purification
• Use with DNaseAlert™ QC System to quantitatively detect both RNases and DNases in the same sample

The RNaseAlert® QC System uses a novel RNA substrate tagged with a fluorescent reporter molecule (fluor) on one end and a quencher on the other. In the absence of RNases, the physical proximity of the quencher dampens fluorescence from the fluor to extremely low levels. When RNases are present, however, the RNA substrate is cleaved, and the fluor and quencher are spatially separated in solution. This causes the fluor to emit a bright green signal when excited by light of the appropriate wavelength. Fluorescence can be readily detected with a filter-based or monochromator-based fluorometer. Since the fluorescence of the RNaseAlert® Substrate increases over time when RNase activity is present, results monitored with a fluorometer can be evaluated kinetically. The sequence of the RNaseAlert® Substrate has been carefully optimized to detect several RNases, including RNase A, RNase T1, RNase I, micrococcal nuclease, S1 nuclease, mung bean nuclease, and Benzonase®.

Rapid and Convenient Protocol
The RNaseAlert® procedure requires just minutes to set up. The lyophilized, fluorescent substrate is reconstituted in the supplied tube and incubated with the test solution for a few minutes. The results are then read on a fluorometer. Samples that noticeably fluoresce compared to the negative control are contaminated and should not be used with RNA. Nuclease-free water and RNase A are provided for use as controls.

Accessory Product:
RNaseAlert® is also fully compatible with the Ambion® DNaseAlert™ QC System (SKU# AM1970). Since the DNaseAlert™ Substrate contains a fluorescent tag that is spectrally distinct from RNaseAlert®, the two kits can be used simultaneously with a fluorometer for quantitative real-time analyses of both RNases and DNases within a single sample.

长度(mm)
宽度(mm)
高度(mm)
重量(kg)
猜你喜欢

在线
客服

在线客服服务时间:09:00-18:00

客服
热线

400-920-3909
客服服务热线 周一至周五(09:00-18:00)

微信
咨询

微信小程序 7X24小时在线咨询