首页> 生物试剂> 其他生物试剂> 其他> AMPLEX RED SPHINGOMYEL 1 KIT,A12220,Invitrogen

AMPLEX RED SPHINGOMYEL 1 KIT,A12220,Invitrogen

市场价: 询价 / 套
在线询价
优    惠: 请询价
订货号 2EQ1569
品牌型号 Invitrogen A12220
货期 询货期
最小订货量 1套
联系我们
  • 400-920-3909
  • 商品介绍
  • 规格参数
  • 包装参数
产品介绍 Product Description
规格
Product Line: Amplex™
Shipping Condition: Wet Ice
Detection Method: Fluorescent
For Use With (Equipment): Fluorometer, Microplate Reader
Label Type: Other Label(s) or Dye(s)
Label or Dye: Amplex® Red
Format: 96-well plate
储存
Store in freezer (-5 to -30°C) and protect from light.
描述

The Amplex® Red Sphingomyelinase Assay Kit provides a sensitive, rapid, and simple fluorometric method for detecting very low concentrations of sphingomyelinase using a fluorescence microplate reader or fluorometer.

See our complete line of Fluorescence Microplate assays.

• Detects sphingomyelinase activity levels as low as 80 µU/mL in a 200 µL assay volume
• Format allows for multiple time point measurements
• Designed for minimal autofluorescence interference

In this enzyme-coupled assay, sphingomyelinase activity is monitored indirectly using 10-acetyl-3,7-dihydroxyphenoxazine (Amplex® Red reagent), a sensitive fluorogenic probe for hydrogen peroxide. Sphingomyelinase hydrolyses the sphingomyelin to yield ceramide and phosphorylcholine. Alkaline phosphatase is added, which hydrolyzes phosphorylcholine to form choline. The choline is then oxidized by choline oxidase to form betaine and hydrogen peroxide. In the presence of horseradish peroxidase, the hydrogen peroxide reacts with Amplex® Red reagent in a 1:1 stoichiometric ratio to generate the highly fluorescent product resorufin.

Because resorufin has absorption and fluorescence emission maxima of approximately 571 nm and 585 nm, respectively, there is little interference from autofluorescence in most biological samples.

Use Amplex® Red Assays for a Broad Range of Investigations
A wide variety of validated Amplex® Red assays are available for studying cell signaling and lipids, neurobiology, inflammation and immune function, and metabolism. We also offer Amplex® UltraRed Reagent (Cat. No. A36006), a second-generation reagent providing greater sensitivity and brighter fluorescence, and the Amplex® Red/UltraRed Stop Reagent (Cat. No. A33855). The Amplex® Red/UltraRed Stop Reagent provides convenience and control by allowing the fluorescence signal-generating reaction to be terminated at a user-determined time point. After addition of the stop reagent, the fluorescence signal remains stable for at least three hours. Custom assay design and packaging are also available.

长度(mm)
宽度(mm)
高度(mm)
重量(kg)
猜你喜欢

在线
客服

在线客服服务时间:09:00-18:00

客服
热线

400-920-3909
客服服务热线 周一至周五(09:00-18:00)

微信
咨询

微信小程序 7X24小时在线咨询