首页> 生物试剂> 抗体和免疫分析> ELISA> Camidanlumab ELISA Kit,96T,DF996028-96T,Abinscience

Camidanlumab ELISA Kit,96T,DF996028-96T,Abinscience

销售价: ¥ 6756.00 / 件
在线询价
优    惠: 请询价
订货号 0BC4765
品牌型号 Abinscience DF996028-96T
库存 有库存
最小订货量 1件
联系我们
  • 400-920-3909
AbinscienceELISA其它型号产品
  • 商品介绍
  • 规格参数
  • 包装参数
技术参数 Specifications
Stability and StorageThe stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% prior to the expiration date under appropriate storage condition.
Detection methodColorimetric
Sample typePlasma, Serum
Assay typeQuantitative
Sensitivity0.156 μg/ml
Range0.31-5 μg/mL
Recovery80-120%
BackgroundCamidanlumab tesirine is an antibody-drug conjugate against CD25, an antigen expressed in several malignancies, including acute lymphoblastic leukemia (ALL) and acute myeloid leukemia (AML). This open-label, dose-escalation and -expansion study (NCT02588092) assessed the safety, activity, pharmacokinetics (PK), and immunogenicity of camidanlumab tesirine in patients with relapsed/refractory ALL/AML. A total of 35 patients (34 AML and 1 ALL) were enrolled and received camidanlumab tesirine intravenously at 3-92 μg/kg once every three weeks (Q3W, n = 26) or 30 or 37.5 μg/kg every week (QW, n = 9). One dose-limiting toxicity of maculopapular rash occurred in the 30 μg/kg QW group; the maximum tolerated dose was not reached. No additional safety concerns or adverse events (AEs) of interest were identified. The most common (>10 % of patients) Grade ≥3 treatment-emergent AEs were febrile neutropenia (25.7 %), lymphopenia, neutropenia, thrombocytopenia or fatigue (all 14.3 %), pneumonia, increased gamma-glutamyltransferase, and hypophosphatemia (each 11.4 %). No signal for serious immune-related AEs such as Guillain-Barré syndrome/polyradiculopathy was observed and there was no evidence of immunogenicity. PK showed rapid clearance with apparent half-life <2 days for conjugated and total antibody, suggesting that Q3W dosing may be insufficient for therapeutic efficacy, and prompting exploration of a QW schedule. Two patients achieved complete responses with incomplete hematologic recovery; one each at 30 and 37.5 μg/kg QW. The trial was terminated during dose escalation due to programmatic reasons other than safety. Hence, recommended dose was not determined.
Alternative NamesADCT-301(unconjugated), HuMax-TAC-ADC, CAS: 921618-45-3
Shipping2-8 ℃
SpecificationsCamidanlumab
NoteFor Research Use Only.
长度(mm)
宽度(mm)
高度(mm)
重量(kg)
猜你喜欢

在线
客服

在线客服服务时间:09:00-18:00

客服
热线

400-920-3909
客服服务热线 周一至周五(09:00-18:00)

微信
咨询

微信小程序 7X24小时在线咨询